Current:Main>Power Amplifier Module
16W B8 GSM 900MHz Power Amplifier Module
- Technical indicators ItemsTransmit link (downlink)Receive link (uplink)Frequency range (MHz)925-960880-915maximum output power42 ± 1dB……
Product Details
- Technical indicators
Items | Transmit link (downlink) | Receive link (uplink) |
Frequency range (MHz) | 925-960 | 880-915 |
maximum output power | 42 ± 1dBm | |
automatic level control | When the input signal level increases by more than 10dB (less than 20dB)The output power should be kept within ±1.5dB of the maximum output power | |
gain (modifiable) | ≤ 55 ± 2 dB | ≤ 18 ±2dB |
Gain adjustment range | ≥ 30dB | |
Gain adjustment step size | ≤ 1dB | |
Gain adjustment error | Gain adjustment range≤20dBThe total error is ≤±1dB in the range of 0-20dB; | |
Gain adjustment range>20dBThe total error is less than or equal to ±1.5dB in the range greater than 20dB | ||
EVM | ≤ 5 %(rms) | |
ACPR | ≤- 45dBc | |
In-band fluctuation | ≤ 3dB | |
Frequency error | Frequency error should be less than or equal to 0.01ppm | |
VSWR (Standing wave ratio) | ≤1.5 | |
Noise Figure | ≤3dB | |
Transmission delay | ≤ 1 μs | |
Maximum damage-free input power | +10dBm ( CW signal ) | -10dBm (CW signal) |
Voltage and current | +28V;≤2.8A | |
working environment | -25~ +55 ℃ | |
test signal | PAPR=9.7, 64QAM, LTE20MHz |
2. Module interface
- The power and monitoring interface adopts the POWER-6 connector, and its pins are defined as follows:
- RF interface: SMA-50KFD

3. Monitoring function
- Module address (default address is 0, can be set);
- PA setting function: power amplifier switch, ALC, ATT attenuation;
- PA query function: module status (including power amplifier switch, output power, reverse power, module temperature, VSWR, ATT, ALC, PA input power or LNA output), alarm status (over-temperature alarm, VSWR alarm, power amplifier fault alarm);
- Over temperature alarm: the alarm threshold is + 85℃, the detected temperature exceeds + 85℃alarm, and the power amplifier is turned off at the same time, and the power amplifier is automatically turned on when +80°C;
- Power amplifier failure alarm: low gain alarm;
- Power amplifier temperature detection: the detection range includes but not limited to -40 ℃~+ 85℃, and the detection accuracy is less than ± 3℃;
- PA forward power detection: total power detection, modulated signal test, detection range 25~46dBm, detection accuracy less than ± 2dBm;
- PA reverse power detection: total power detection, modulated signal test, detection range 25~46dBm, detection accuracy less than ± 2dBm;
- PA input power detection: total power detection, modulation signal test, detection range -20~4dBm, detection accuracy less than ± 2dBm;
- LNA setting function: ATT attenuation
- LNA query function: ATT attenuation
4. Dimensions